设为首页 | 加入收藏 | 关于华誉 | 联系我们

欢迎访问济南华誉涂装设备有限公司官方网站!

全国咨询热线

0531-83542917

139-5416-0118

新闻中心

联系我们

电话:0531-83542917 61321776

手机:13954160118

传真:0531-83383866 61321776

邮编:250212

地址:山东章丘辛寨经济开发区

您现在的位置:首页 > 新闻中心 > 公司新闻

公司新闻

关于环保除尘设备高压控制柜故障指示灯亮原因解析

文章发布: 发表时间: 2017-06-05 11:05:53

a)环保除尘设备除尘器室内发作持久短路,可能有以下几个因素:
(a) environmental protection dust removal equipment, dust catcher interior lasting short-circuit, may have the following factors:
˙阴极线断线;
The cathode, line break;
˙粉尘堆积在阳极板上,而且和阴极线体系触摸;
After the dust accumulation on the anode plate and the cathode, and the touch line system;
˙重锤掉落;
I drop hammer;
​˙绝缘子等破损、被严峻污染,绝缘不良。
So, be serious damage, insulator pollution, poor insulation.
b)电压表、电流表大幅振荡,最终,电压表的指针几乎在零邻近继续5~6秒,高压控制柜毛病指示灯亮。这种状况可能有以下几个因素:
B) the voltmeter and ammeter oscillate greatly. Eventually, the voltmeter's pointer is near zero for about 5~6 seconds, and the faulty indicator light of the high voltage control cabinet is on. This situation may have the following factors:
˙阴极线体系的重锤从下部结构上偏离,阴极下部结构对阴极线的固定效果失掉。
After the cathode line system deviates from the lower part of the structure weight, lose the fixed effect on the cathode line cathode structure.
˙金属丝,施工垃圾等异物残留在室内;
- wire, construction waste residue in the room;
˙因为除尘器室内的气体散布不均,致使某有些气体偏流、电极间的间隔不整齐和阳极板变形发作部分的接连火花放电,致使短路,还有阴极线振荡,呈现周期性火花放电。
Because the gas dust remover, the indoor distribution is uneven, resulting in a drift, some gas irregular space between electrodes and anode plate deformation attack part of the successive spark discharge, resulting in the short circuit, and the cathode line oscillation, periodicity of spark discharge.
2.4.2电压表在电压低的地方大幅度振荡
The 2.4.2 voltmeter oscillates substantially at low voltage
因为环保除尘设备 http://www.huayutuzhuang.com/ 的喷雾嘴洗净不良,粉尘过度附着在集尘板上。当粉尘一会儿落下的时候,大多数状况会发作这么的疑问。通过添加洗净次数,使附着粉尘落下,大有些状况下大幅度振荡就会中止。依然大幅度振荡,而且火花放电变得激烈、阴极线振荡、高压控制柜毛病指示灯亮。如果呈现此种状况,堵截一次电荷,数分钟后再次接通电荷。而且请承认喷雾嘴没有阻塞。
Because of the poor cleaning of the spray nozzle of the environmental protection dust collector, the dust is excessively stuck on the dust collecting board. When dust falls for a while, most of the conditions can cause such doubts. By adding a number of cleaning, so that the dust attached to fall, in some cases, a large oscillation will be suspended. The oscillation is still very large, and the spark discharge becomes violent, the cathode line oscillates, and the high voltage control cabinet trouble indicator light is on. If this occurs, the charge is intercepted and the charge is switched on again in a few minutes. And please admit that the spray nozzle is not blocked.